Ethernet Automatic Protection Switching
ExtremeWare XOS 11.3 Concepts Guide
414
Flushing the FDBs
When a controller goes into or out of the “blocking” state, the controller sends a “flush fdb” message to
flush all of the FDBs of the switches in its segments. Each switch in the path of the “flush fdb” message
flushes its FDB.
In a network with multiple EAPS ports in the blocking state, the “flush fdb” message gets propagated
across the boundaries of the EAPS domains.
Creating and Deleting a Shared Port
To configure a common link, you must create a shared port on each switch belonging to the common
link. To create a shared port, use the following command:
create eaps shared-port <ports>
where
ports
is the common link port.
NOTE
A switch can have a maximum of two shared ports.
To delete a shared port on the switch, use the following command:
delete eaps shared-port <ports>
Defining the Mode of the Shared Port
The shared port on one end of the common link must be configured to be the controller. This is the end
responsible for blocking ports when the common link fails thereby preventing the superloop.
The shared port on the other end of the common link must be configured to be the partner. This end
does not participate in any form of blocking. It is responsible for only sending and receiving health-
check messages.
To configure the mode of the shared port, use the following command:
configure eaps shared-port <ports> mode <controller | partner>
Configuring the Link ID of the Shared Port
Each common link in the EAPS network must have a unique link ID. The controller and partner shared
ports belonging to the same common link must have
matching
link IDs. No other instance in the
network should have that link ID.
To configure the link ID of the shared port, use the following command:
configure eaps shared-port <ports> link-id <id>
Содержание ExtremeWare XOS 11.3
Страница 20: ...Contents ExtremeWare XOS 11 3 Concepts Guide 20...
Страница 25: ...1 Using ExtremeWare XOS...
Страница 26: ......
Страница 38: ...ExtremeWare XOS Overview ExtremeWare XOS 11 3 Concepts Guide 38...
Страница 58: ...Accessing the Switch ExtremeWare XOS 11 3 Concepts Guide 58...
Страница 146: ...Configuring Slots and Ports on a Switch ExtremeWare XOS 11 3 Concepts Guide 146...
Страница 218: ...Status Monitoring and Statistics ExtremeWare XOS 11 3 Concepts Guide 218...
Страница 240: ...Virtual LANs ExtremeWare XOS 11 3 Concepts Guide 240...
Страница 248: ...Virtual Routers ExtremeWare XOS 11 3 Concepts Guide 248...
Страница 278: ...Access Lists ACLs ExtremeWare XOS 11 3 Concepts Guide 278...
Страница 288: ...Routing Policies ExtremeWare XOS 11 3 Concepts Guide 288 entry deny_rest if then deny...
Страница 344: ...Security ExtremeWare XOS 11 3 Concepts Guide 344...
Страница 393: ...2 Using Switching and Routing Protocols...
Страница 394: ......
Страница 454: ...Spanning Tree Protocol ExtremeWare XOS 11 3 Concepts Guide 454...
Страница 484: ...Extreme Standby Router Protocol ExtremeWare XOS 11 3 Concepts Guide 484...
Страница 514: ...IPv4 Unicast Routing ExtremeWare XOS 11 3 Concepts Guide 514...
Страница 530: ...IPv6 Unicast Routing ExtremeWare XOS 11 3 Concepts Guide 530...
Страница 538: ...RIP ExtremeWare XOS 11 3 Concepts Guide 538...
Страница 556: ...OSPF ExtremeWare XOS 11 3 Concepts Guide 556...
Страница 566: ...OSPFv3 ExtremeWare XOS 11 3 Concepts Guide 566...
Страница 589: ...3 Appendixes...
Страница 590: ......
Страница 640: ...CNA Agent ExtremeWare XOS 11 3 Concepts Guide 640...
Страница 670: ...Glossary ExtremeWare XOS 11 3 Concepts Guide 670...
Страница 698: ...Index ExtremeWare XOS 11 3 Concepts Guide 698...