Traffic Groupings
ExtremeWare XOS 11.3 Concepts Guide
305
To verify settings on ports or VLANs, use the following command:
show ports {mgmt | <port_list>} information {detail}
BlackDiamond 8800 family of switches and Summit X450 switch display.
You display which QoS profile, if
any, is configured on the BlackDiamond 8800 family of switches and the Summit X450 switch using the
show ports <port_list> information detail
command. Following is a sample output of this
command for an BlackDiamond 8810 switch:
Port: 8:1
Virtual-router: VR-Default
Type: EW
Random Early drop: Disabled
Admin state: Enabled with auto-speed sensing auto-duplex
Link State: Active
Link Counter: Up 1 time(s)
VLAN cfg:
Name: Default, Internal Tag = 1, MAC-limit = No-limit
STP cfg:
s0(disable), Tag=(none), Mode=802.1D, State=FORWARDING
Protocol:
Name: Default Protocol: ANY Match all protocols.
Trunking: Load sharing is not enabled.
EDP: Enabled
DLCS: Unsupported
lbDetect: Unsupported
Learning: Enabled
Flooding: Enabled
Jumbo: Disabled
BG QoS monitor: Unsupported
Egress Port Rate: No-limit
Broadcast Rate: No-limit
Multicast Rate: No-limit
Unknown Dest Mac Rate: No-limit
QoS Profile: Qp3 Configured by user
Ingress Rate Shaping : Unsupported
Ingress IPTOS Examination: Disabled
Egress IPTOS Replacement: Disabled
Egress 802.1p Replacement: Disabled
NetLogIn: Disabled
Smart redundancy: Enabled
Software redundant port: Disabled
NOTE
To ensure that you display the QoS information, you must use the
detail
variable.
BlackDiamond 10K switch display.
You display information on the egress QoS profiles and the ingress
QoS profiles (shown as Ingress Rate Shaping), as well as the minimum and maximum available
bandwidth and priority on the BlackDiamond 10 K switch using the
show ports <port_list>
information detail
command. The display is slightly different for a 1 Gbps port and for a 10 Gbps
port.
Содержание ExtremeWare XOS 11.3
Страница 20: ...Contents ExtremeWare XOS 11 3 Concepts Guide 20...
Страница 25: ...1 Using ExtremeWare XOS...
Страница 26: ......
Страница 38: ...ExtremeWare XOS Overview ExtremeWare XOS 11 3 Concepts Guide 38...
Страница 58: ...Accessing the Switch ExtremeWare XOS 11 3 Concepts Guide 58...
Страница 146: ...Configuring Slots and Ports on a Switch ExtremeWare XOS 11 3 Concepts Guide 146...
Страница 218: ...Status Monitoring and Statistics ExtremeWare XOS 11 3 Concepts Guide 218...
Страница 240: ...Virtual LANs ExtremeWare XOS 11 3 Concepts Guide 240...
Страница 248: ...Virtual Routers ExtremeWare XOS 11 3 Concepts Guide 248...
Страница 278: ...Access Lists ACLs ExtremeWare XOS 11 3 Concepts Guide 278...
Страница 288: ...Routing Policies ExtremeWare XOS 11 3 Concepts Guide 288 entry deny_rest if then deny...
Страница 344: ...Security ExtremeWare XOS 11 3 Concepts Guide 344...
Страница 393: ...2 Using Switching and Routing Protocols...
Страница 394: ......
Страница 454: ...Spanning Tree Protocol ExtremeWare XOS 11 3 Concepts Guide 454...
Страница 484: ...Extreme Standby Router Protocol ExtremeWare XOS 11 3 Concepts Guide 484...
Страница 514: ...IPv4 Unicast Routing ExtremeWare XOS 11 3 Concepts Guide 514...
Страница 530: ...IPv6 Unicast Routing ExtremeWare XOS 11 3 Concepts Guide 530...
Страница 538: ...RIP ExtremeWare XOS 11 3 Concepts Guide 538...
Страница 556: ...OSPF ExtremeWare XOS 11 3 Concepts Guide 556...
Страница 566: ...OSPFv3 ExtremeWare XOS 11 3 Concepts Guide 566...
Страница 589: ...3 Appendixes...
Страница 590: ......
Страница 640: ...CNA Agent ExtremeWare XOS 11 3 Concepts Guide 640...
Страница 670: ...Glossary ExtremeWare XOS 11 3 Concepts Guide 670...
Страница 698: ...Index ExtremeWare XOS 11 3 Concepts Guide 698...