2 Unlock the module in one of the following ways:
•
On a module without red lines on the screw heads, turn each captive screw counter-clockwise
and verify that the yellow band around the captive screw head of each injector/ejector handle is
completely visible (
Figure 68: Unlocking a Module
on page 96). This position ensures that the
module is unlocked.
•
On a module with red lines on the screw heads, turn each captive screw counter-clockwise one-
quarter turn (90 degrees, as shown in
Figure 68: Unlocking a Module
on page 96). Verify that
the red line on each captive screw is in a horizontal position (
Figure 69: Indications that the
Module is Unlocked
on page 97). This position ensures that the MSM or I/O module is unlocked.
Caution
Be sure to turn each captive screw only 90 degrees or one-quarter turn counter-
clockwise. Loosening the captive screws beyond 90 degrees will damage the injector/
ejector handles on the module.
Figure 68: Unlocking a Module
Installing Modules and Establishing Initial Management Access
BlackDiamond 8800 Hardware Install Guide
96