Table 36: Specifications for the AC SSI PS Model # 60020/PS2336 (700/1200 W AC
PSU) (continued)
Input
Nominal input: 100 to 240 VAC, 60/50 Hz, 10 A max
AC voltage input range: 90 to 264 VAC
Maximum input amperages:
7 A @ 200 VAC (high-line)
10 A @ 90 VAC (low-line)
AC line frequency: 47 to 63 Hz
PS input socket: IEC 320 C14
Minimum wire size: 16 AWG (1.31mm2) copper stranded
Output
DC output:
48 VAC, 24 A/12 VAC, 4 A (high-line)
48 VAC, 13.5 A/12 VAC, 4 A (low-line)
DC output power (W): 700 to 1200 W
Power supply cord selection
Refer to
Cable Routing for PoE Devices
on page 143.
AC power supply input socket
IEC 320 C14
Minimum wire size
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet
Operating conditions
Operating temperature: 0°C to 40°C
Storage temperature: –40°C to 70°C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s2 (3 g)
Table 37: Specifications for the AC PS Model # 41050 (600/900 W AC PSU)
Compatible with the BlackDiamond 8806 switch
Typical configuration
3 power supplies
Full configuration
6 power supplies
Input
Nominal input voltage: 100 to 240 VAC, 60/50 Hz, 8 A max
Voltage input range/frequency range: 90 to 264 VAC
AC line frequency: 47 to 63 Hz
Maximum input amperages:
5 A @ 200 VAC (high-line)
8 A @ 90 VAC (low-line)
Output
DC output:
48 VAC, 18 A/12 VAC, 4 A (high-line)
48 VAC, 11.5 A/12 VAC, 4 A (low-line)
DC output power (W): 600 to 900 W
Power supply cord selection
Refer to
Cable Routing for PoE Devices
on page 143.
AC power supply input socket
IEC 320 C14
Minimum wire size
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet
Operating conditions
Operating temperature: 0°C to 40°C (32°F to 104°F)
Storage temperature: –40°C to 70°C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s2 (3 g)
Technical Specifications
BlackDiamond 8800 Hardware Install Guide
159