ES 2050/51
Manual regeneration initiation
13
Manual regeneration initiation.
A regeneration may be manually initiated at any time. Press the "REGENERATION INITIATION" key
indicated by the symbol
, after 2 seconds regeneration of the on line unit is initiated.
With duplex installations operating in standby mode the stand by unit is brought into
service.
If manual initiation is attempted during a period in which the controller has been
programmed to prohibit regeneration (section 3.1 of the programming instructions)
the time at which regeneration will be initiated will appear with the current time in the
LCD display. In a duplex plant, operating in standby mode, the stand by unit is brought
into
service.
If the prohibited time function is already activated the regeneration will initiate, i.e.
the prohibited time function will be overridden.
The counter is reset to the calculated capacity after the regeneration.
If the unit has been set to initiate a regeneration after a fixed time has elapsed,
(section 4.1 of the programming instructions) the interval timer is reset to its
programmed value and restarted.
If a minimum time between regeneration’s has been programmed (section 5.1 of the
programming instructions), the timer will be overridden and reset.