Locking component signals
The locking components indicate events with a host of visual and acoustic signals.
Signal
number
Event
Visual
signal
*)
Acoustic
signal
*)
Note
Signal 1 Authorised medium
mmmmm
Signal 2 End of release
ttttt
Signal 3 Medium rejected
-
-
-
hh-hh-hh-hh
Signal 7
Battery empty
Indicated in AirKey
online administration
as "Battery empty")
--
--
-
-
h----h----h--
--h----
1000 unlocking pro-
cesses or 2 weeks of
standby are guaran-
teed following the first
signals (at room tem-
perature and when
using cards or key
tags).
The signal is shown
regularly upon insert-
ing the battery instead
of signal 8 and upon
unlocking before signal
1.
Signal 8
Insert battery or re-
set component
--
--
tt—mm—hh
Signal 9
Medium without EVVA
segmentation;
external card
---
Signal
10
Hardware error
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
mmm---
mmm---
mmm---
mmm---
mmm---
mmm---
mmm---
mmm---
mmm---
mmm---
For instance, indicates
a faulty connection
between thumb turn
and electronics mod-
ule.
Signal
11
Firmware update
-
-
-
-
…
(1s period,
12ms pulse)
-------…
Duration: until com-
munication is com-
plete.