OVER SPEED LEVEL
Threshold above which an overspeed alarm is generated.
8:36#
5(&(,9(
#
(5525
5703 RCV.INHIBI
Disables the 5703 alarm. This only applies for 5703 slaves, if enabled the drive will
trip if it stops receiving valid 5703 messages from its master.
63(('
#
)(('%$&.
SPD.FBK.DELAY
Delay before the speed feedback alarm is triggered.
SPD.FBK.THRESHD
The value of speed error below which the alarm is automatically inhibited.
SPD.FBK.INHIBI
Disables the speed feedback trip. This is necessary if the drive is to operate in a mode
where there is a speed error, for example a drive operating in torque control.
',$*1267,&6
OPERATING MODE
Diagnostic.
DRIVE START
Diagnostic.
DRIVE ENABLE
Diagnostic.
READY
Diagnostic.
RUN
Diagnostic.
HEALTH STORE
Diagnostic.
HEALTH WORD
Diagnostic.
FIRST ALARM
Diagnostic.
HEALTHY
Diagnostic.
HEALTH OUTPUT
Diagnostic.
&$/,%5$7,21
00,
#
(175,(6
........ENCODER LINES [131] = 2048
........ENCODER SUPPLY [774] = 50 %
........MAX SPEED RPM [130] = 1500 RPM
........BASE FREQUENCY [448] = 50.0 Hz
........MOTOR VOLTS [486] = 415 VOLTS
........MOTOR RATING RMS [134] = 1.0 AMPS
........NO.OF POLES [399] = 4
........NAMEPLATE RPM [135] = 1440 RPM
3$5$0(7(56
ENCODER LINES
The exact number of lines on the encoder. Failure to enter this value correctly will
cause loss of torque and incorrect results from the Autotune.
ENCODER SUPPLY
Sets the encode supply voltage, the actual value should read with a Multi-meter. The
voltage range is approximately 10 to 20volts with 50% being 10v.
MAX SPEED RPM
Motor top speed setting, equates to 100% setpoint. This may be adjusted to suit your
process.
BASE FREQUENCY
Base speed of the motor usually 50 or 60Hz.
MOTOR VOLTS
Actual motor volts from motor nameplate, or motor data sheet.
MOTOR RATING RMS
The motor rating current in amps from the motor nameplate. For the best
performance, this value should be at least 50% of the drive rating.
If you are derating your motor for “Inverter” use then you should use the non-derated
value of current.
NO OF POLES
Number of poles in the motor; must be divisible by two, e.g. 2,4,6,8.
NAMEPLATE RPM
Motor speed, taking slip into account. This value will be provided by the motor
manufacturer, usually on the motor nameplate.