Nodes 5-8
햴
Ringnet Communications
Connect the ringnet cable to the four terminals 1A to 2B. These terminals are used
for connecting the RKD node onto the ringnet – see the following connection diagram and cable type table.
햵
Power supply & current consumption
To function correctly, the RKD requires 12Vdc which should be
supplied either directly from the controller power supply unit or from a remote power supply unit.
Current Consumption - Quiescent State: 150mA (backlight off), Maximum: 300mA.
햶
Inputs
The RKD node has two on-board zone inputs. These inputs are monitored using dual EOL supervision as
wired in the following illustration:
.
햷
Output
The RKD has 1 on-board 1Amp single pole changeover
relay, which can be assigned to any of the system outputs.
See
Node Configure->Outputs
in
3GS Programming
for further
information.
햸
Tampers
The RKD Node monitors both front and back tampers.
The front tamper is closed once the terminal block cover is
secured.
햹
Keys
The keys are used for code entry, setting/arming and unsetting/disarming the system, and accessing the
menus detailed in the Software section. For further information on keys, see Typing Text in 3GS Programming.
IMPORTANT !
Never run Keypad wires alongside telephone wires, high
voltage wires, or transmitting antennae. Keypad wires should be wired
separately and not in the same cable with other devices (telephone, PIRs,
and so on). Do not use the keypad as a junction box for wiring power to
sensors. Install the keypad at human eye height (160-180 cm) for clear
display visibility.
cable type
maximum distance
between nodes
Belden 9502 (screened)
500m
UTP Category: 5 (solid core)
1000m
Belden 9829
1000m
I1
COM
I2
2K2
2K2
2K2
2K2
description
value
zone status
OPEN
4400
Zone open
CLOSED
2200
Zone closed
DISCON
30 000
Zone disconnected
SHORT
< 1400
Zone shorted
DC SUBS
Variable
DC Voltage substitution
N/O
N/C
COMM
N/C : Normally
Closed
N/O : Normally
Open
+12V 0V
Содержание 3GS
Страница 4: ...Introduction iv...
Страница 12: ...Introduction 8...
Страница 14: ...1...
Страница 18: ...System Overview 1 6...
Страница 20: ......
Страница 22: ...Hardware Overview 2 4 SYSTEM CONFIGURATION The following diagram shows a typical configuration of the system...
Страница 26: ......
Страница 34: ......
Страница 38: ...Intelligent PSUs 4 6...
Страница 40: ......
Страница 97: ...Issue 4 5 August 2005 Nodes 5 59...
Страница 98: ...Issue 4 5 August 2005 Nodes 5 61...
Страница 100: ......
Страница 106: ...3GS Technical Manual...
Страница 116: ...3GS Technical Manual 7 12 Programming Overview Issue 4 5 August 2005 3GS Initial Setup Menu...
Страница 118: ...3GS Technical Manual...
Страница 146: ...3GS Technical Manual Issue 4 5 August 2005 Programming Menus 8 31 Node Configure Inputs Menu...
Страница 153: ...3GS Technical Manual Issue 4 5 August 2005 8 38 Programming Menus Service Mode Test Menu...
Страница 155: ...3GS Technical Manual Issue 4 5 August 2005 8 40 Programming Menus Service Mode Monitor Menu...
Страница 217: ...3GS Technical Manual Issue 4 5 August 2005 8 108 Programming Menus...
Страница 218: ...3GS Technical Manual Issue 4 5 August 2005 Programming Menus 8 109...
Страница 220: ......
Страница 222: ...3GS Version 5 User Guide 9 5 3GS SYSTEM KEYPAD DISPLAY...
Страница 254: ...3GS Version 5 User Guide 9 37 Some examples of Alert Messages...
Страница 262: ...3GS Version 5 User Guide 9 45 User name max 24 characters User no 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32...
Страница 264: ......
Страница 265: ...I n t h i s c h a p t e r HHT Overview 10 3 Main Menu 10 5 HAND HELD TERMINAL HHT 10...
Страница 266: ......
Страница 280: ......
Страница 288: ......
Страница 290: ......
Страница 293: ...Issue 4 5 August 2005 DM1200 Digital Communicator Modem 12 5...
Страница 301: ...I n t h i s c h a p t e r Network Router Overview 13 3 Sample Connection Diagram Scenarios 13 4 NETWORK ROUTER 13...
Страница 302: ......
Страница 304: ...Network Router 13 4 SAMPLE CONNECTION DIAGRAM SCENARIOS...
Страница 308: ...Network Router 13 8...
Страница 310: ......
Страница 316: ...IntelliBell 14 8 SELF ACTIVATING BELL To connect a Self Activating Bell SAB to the 3GS system see the following diagram...
Страница 318: ......
Страница 338: ...Issue 4 5 August 2005 Technical Specifications 15 23...
Страница 339: ...I n t h i s c h a p t e r 3GS Overview 16 5 Installing 3GS 16 6 Installing the Dongle 16 7 Upgrading 16 8 16 PC SOFTWARE...
Страница 340: ...1...
Страница 346: ......
Страница 366: ...17 22...
Страница 367: ...I n t h i s c h a p t e r Introduction to CiTeC II 18 3 CITEC II INSTALLATION 18...
Страница 368: ......
Страница 370: ...CiTeC II Installation 18 4...
Страница 377: ...Issue 4 5 August 2005 19 7...
Страница 378: ...19 8...
Страница 385: ......
Страница 386: ......