![ETC transtechnik FDX2000 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/etc/transtechnik-fdx2000/transtechnik-fdx2000_operating-manual_2431362038.webp)
Feedback connectors
These two connectors are used to capture the I/V feedback messages sequentially from the modules.
With the help of the actual values all 96 circuits can be managed using time-division multiplex
technology.
The modules are arranged in groups of 6, each module returns a low-active signal output for current and
voltage, in other words, the feedback occurs on a total of 12 lines (U0 through U5 and I0 through I5).
The 96 circuits are queried, one after the other, in 16 groups using the high-active signals SEL0 through
SEL15. The I/V signal outputs on the modules are implemented using open collector drivers and can
thus easily be switched in parallel using wired-Or technology.
If SEL0 is applied, the current and voltage feedback messages for modules 1 through 6 are queried.
Then SEL1 is used to activate feedback for the next circuit group, circuits 7 through 12. Using the 16
SEL signals all 96 modules are queried one after another. A complete query cycle takes roughly 5 ms.
The inputs and outputs from two FDX2000 units can be directly switched in parallel in redundant
installations (the SEL outputs are decoupled using diodes, queries are synchronized with SEL0).
I/V error: see page 7.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Ass.
V–(0) V–(2) C–(4) C–(0) C–(2) C–(4)
SEL11
SEL9 SEL7 SEL5 SEL3 SEL1 Gnd
Pin
14
15
16
17
18
19
20
21
22
23
24
25
Ass.
V–(1) V–(3) V–(5) C–(1) C–(3) C–(5)
SEL10
SEL8 SEL6 SEL4 SEL2 SEL0
Assignments for the upper feedback plug
(6 current and 6 voltage inputs, SEL signals SEL0 through SEL11)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Ass.
V–(1) V–(3) V–(5) C–(1) C–(3) C–(5)
–
–
–
–
SEL15 SEL13
Gnd
Pin
14
15
16
17
18
19
20
21
22
23
24
25
Ass.
V–(2) V–(4) V–(6) C–(2) C–(4) C–(6)
–
–
–
–
SEL14 SEL12
Assignments for the lower feedback plug
(6 current and 6 voltage inputs, SEL signals SEL12 through SEL15)
Select
signal
SEL0
(U)
SEL1
(U)
SEL2
(U)
SEL3
(U)
SEL4
(U)
SEL5
(U)
SEL6
(U)
SEL7
(U)
Output
stages
1–6
7–12
13–18
19–24
25–30
31–36 37–42 43–48
Select
signal
SEL8
(U)
SEL9
(U)
SEL10
(U)
SEL11
(U)
SEL12
(L)
SEL13
(L)
SEL14
(L)
SEL15
(L)
Output
stages
49–54
55–60
61–66
67–72
73–78
79–84 85–90 91–96
Assignment of the 16 SEL signals to the 96 dimmer.
(U) = upper feedback connector, (L) = lower feedback connector.
– 34 –
FDX2000 Vers. 4.0.0