Main menu
Open
•
Appears once the equipment has been started
•
From all other menus:
Hit the
[ESC]
button until the main menu appears
Purpose
Shows a range of particularly important operating statuses or error messages
DMX
Status of the DMX inputs A and B
A
/
B
DMX input A/B is receiving valid signal
-
No input signal available
COM
Status of RS-485 communication
ok
Input signal is available
--
No input signal available
NET
Status of Ethernet communication
ok
Input signal is available
--
No input signal available
DIM
Status of dimmer control
ok
Dimmer control enabled, no error
off
Dimmer control disabled using the on/off switch
on the front panel
dis
Dimmer control disabled
err
C error or V error, on at least one dimmer, see below
sys
General: Error: Scrolling using
[PAGE]
or the rotating knob will take you to the
detailed display
see "System error", on page 10.
C error, V error
C error
Current error, for example, spotlight defective/not fitted or circuit breaker tripped
V error
Voltage error, for example, consumer short-circuited or circuit breaker tripped
C and V errors can only be displayed correctly if the associated dimmer is equipped with a
current and voltage measuring facility.
From the main menu, you can scroll through the top-level menus. The top-level menus contain the
following functions:
•
Display of important operating statuses or error messages
•
Menus which allow you to configure important basic settings.
ID: Numbered consecutively beginning with
M01
.
•
Menus that take you to the next menu level. Here you can make detailed settings.
ID:
[EDIT]
.
Open menus
•
Hit the
[ESC]
button until the main menu appears
•
Use
[PAGE]
or the encoder to scroll through the menus
Dimmer status .
Displays the status of the dimmer. This shows the number of dimmers
set, see page 18.
Example: All dimmers OK
Dimmer state:
96 dimmers ready
I/V errors are only shown correctly if C and V feedback for each dimmer is set according
to the dimmer set-up. See the
D08
Feedback/Type
menu, page 14.
Example dimmer error:
•
V error for 5 of 96 dimmers with V monitoring
Dimmer error
V: 5/96 C: 2/96
FDX2000 Vers. 4.0.0
– 7 –