The following curves are available:
1=Linear
linear to power, corresponds to older transtechnik dimmers with „studio curve“
2=Stage1
linear to power, with correction for the stage operation
3=Stage2
traditional stage curve
4=Log
logarithmic or voltage linear, for 115 V at an output level of 50 %
5=Fluour1
Nesys - fluorescent devices
6=Fluour2
fluorescent lamps
7=Pow/2
half power
8=10%
switching curve
9=VIP90
VIP90 - ballast
10=ANDI
old Strand dimmer
If the nominal output voltage in D03 is 230 V, whereas the input voltage is 240 V, the dimmer processor
ensures that even at an output level of 100%, a voltage of just 230 V is output. Fluctuations in input
voltage are stabilized in this way. Only dimmer type Nondim switches through the entire curve without
phase control.
D03, Output voltage at 100% control level
The output voltage can be set for 100% control level individually for each
dimmer. Assumed that 'Dimmer' has been selected in the
D01
Dimmer
type
menu (not
Nondim
, or
Blind
).
Value range:
100V
through
300V
Factory setting:
230V
Vmax (100%) D03
1-96: 235V
Open
•
Hit the
[ESC]
button until the main menu appears
•
Use
[PAGE]
or the encoder to scroll to the
M06
Dimmer
menu
•
[EDIT]
takes you to the most recently called dimmer menu
Dxx
•
Use
[PAGE]
or the encoder to scroll to the
D03
Vmax (100%)
menu
D04, Preheat.
The preheat intensity can be set individually for each dimmer
Accuracy: 0 through 10% in steps of 0.1%, above in 1% steps.
Value range:
---
(0%) through
100%
Factory setting:
---
Preheat D04
1-96: 3.5%
Open
•
Hit the
[ESC]
button until the main menu appears
•
Use
[PAGE]
or the encoder to scroll to the
M06
Dimmer
menu
•
[EDIT]
takes you to the most recently called
Dxx
dimmer menu
•
Use
[PAGE]
or the encoder to scroll to the
D04
Preheat
menu
D05, Control level limit
The control level can be limited individually for each dimmer.
Value range:
0%
through
99%
, 100% =
---
Factory setting:
---
(no limit)
Limit D05
1-96: 70%
Open
•
Hit the
[ESC]
button until the main menu appears
•
Use
[PAGE]
or the encoder to scroll to the
M06
Dimmer
menu
•
[EDIT]
takes you to the most recently called
Dxx
dimmer menu
FDX2000 Vers. 4.0.0