![ETC transtechnik FDX2000 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/etc/transtechnik-fdx2000/transtechnik-fdx2000_operating-manual_2431362012.webp)
•
C error for 2 of 96 dimmers with C monitoring
M01, DMX sources
It is possible to merge the two input lines, DMX and Ethernet, in any way
you choose.
Input merge M01
DMX:AB ETH: 5 7
DMX: Switching in the DMX input
--
No DMX line
A-
DMX line A
-B
DMX line B
AB
Both DMX lines
NET:
Assignment of universes from Ethernet. Each port can handle two
sources (main, backup)
Value range:
-
,
1
through
32
Factory setting: 1 / 1
In standard operating mode both universe numbers always have to be the same (identical)
M02, DMX start address
Setting DMX start address of the device.
Value range:
1
through
512, single
Factory setting:
1
DMX start M02
address: 123
If the DMX address is set so high that the "last" dimmer has an address that is higher than
512, these dimmers are controlled with 0%.
Setting allows you to assign individual DMX addresses to each dimmer
within the cabinet.
Address values can be assigned from dimmer submenu M13, DMX
address, only if DMX start is set to “single”.
DMX start M02
address: single
M03, Communication address
Setting the address of the device for communication, assignment of
main or backup device.
Value range address:
off
,
1
through
99
COM M03
address: 98 A
Value range device status:
(only for Ethernet
communication)
A
,
B
A: device = main device,
B: device = backup device.
Factory setting:
off
COM M03
address: off
M04, IP address
Factory setting:
192.009.200.000
IP address M04
192.009.200.000
Repeatedly pressing
[EDIT]
selects the numerical value that is to be modified (group of three).
– 8 –
FDX2000 Vers. 4.0.0