List of factory settings
The dimmer processor can be reset to the factory settings at the touch of a button, see page 20.
Parameter
Value
Source of the dimmer control signals
DMX lines A and B
Station address
Off
IP address
192.009.200.000
DMX start address
-
Dimmer control
On
Menu language
Deutsch
Display contrast
50%
Dimmer type
All: Dimmer
Dimmer curves
All: linear
Output voltage at 100% control level
All: 230 V
Preheat output level
All: 0%
Output voltage limit
All: none
Switch point for Nondim
All
10% / 10%
Analog signal is used
All: No
Type of dimmer feedback
All: -/V
Dimmer feedback
All: On
Follow-up time for intensity changes
All: 160 mms / 160 mms
Network protocol
AVAB/UDP
Logical network
0
IP net mask
255.255.255.000
Address of the IP gateway
192.009.200.254
Number of dimmers
96
Behavior in the event of failure of input signal
Blackout after 5 s
Global dimmer feedback
On
Temperature sensors
Both on
Overtemperature warning
Both sensors set to 70 °C
Overtemperature shutdown function
Both sensors set to 85 °C
Specification for input voltage
3 x 230 V
Weighting factor for all presets
0%
Fade in/out times for presets
0.0 s / 0.0 s
All stored presets
Deleted
FDX2000 Vers. 4.0.0
– 31 –