![ETC transtechnik FDX2000 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/etc/transtechnik-fdx2000/transtechnik-fdx2000_operating-manual_2431362014.webp)
Error messages
Errors are indicated by appropriate messages. These error messages are shown in the topmost menu
level and, in the same way as with all other menu pages, you can scroll through these using the
[PAGE]
button or the encoder
In the event of an error occurring, the appropriate messages will be inserted between the main menu
and the
Dimmer status
menu. Error messages will continue to be displayed until the error stops
occurring. If several errors occur at the same time, they will be indicated using the following order of
priority:
•
Temperature-related error (over-temperature)
•
Error at the analog-digital converter
•
Phase error.
The main menu itself already indicates, with a sys message in the DIM,
that error messages exist.
DMX:A B COM: ok
ETH: ok DIM:sys
Messages
Warning: Temperature in the dimmer cabinet is too high.
System error:
Overtemperature
Error at the AD-converter The device is operating in a form of emergency
operation.
•
Fluctuations in input voltage are not stabilized.
•
Analog control voltages are not taken into consideration.
•
If the overtemperature deactivation function is activated the device will
be switched off when it reaches 85 °C.
System error:
AD-Converter
One or more phases of input voltage are missing.
Possible displays:
L1
,
L2
,
L3
; in any combination.
System error:
Phase L1
System error:
Phase L1 L3