temperature. The shutdown temperature can be set in the
S10
Dimmer off
menu, see page 20.
The
S09
Overtemperature warning
menu is only displayed if at least one of the temperature sensors
is activated in the
S08
menu, see page 19.
If one of the two sensors is not activated in menu
S08
you will not be able to set a warning
temperature for that sensor.
S10, Overtemperature shutdown
The dimmer processor can be set to shutdown automatically when a
specified internal temperature has been reached. This shutdown
temperature can be set separately for each of the two sensors fitted.
Value range:
0°
through
99°,
---
(no shutdown)
Factory setting:
85°
for both sensors
Dimmer off S10
at temp:85°/85°
Dimmer off S10
at temp:---/---
Open
•
Hit the
[ESC]
button until the main menu appears
•
Use
[PAGE]
or the encoder to scroll to the
M07
System
menu
•
[EDIT]
takes you to the most recently called system menu
Sxx
•
Use
[PAGE]
or the encoder to scroll to the
S10
Dimmer off
menu
Pressing the
[EDIT]
button once allows you to set the shutdown temperature for sensor 1, pressing
[EDIT]
again allows you to set the shutdown temperature for sensor 2.
If the shutdown temperature is set to a value below the current warning temperature, the dimmer
processor automatically sets the warning temperature to 1 degree below the shutdown temperature. The
warning temperature can be set in the
S09
Overtemperature warning
menu, see page 19.
The
S10
Dimmer off
menu is only displayed if at least one of the temperature sensors is activated
in the
S08
menu, see page 19.
If one of the two sensors is not activated in menu
S08
you will not be able to set a warning
temperature for that sensor. The dimmer processor then shows
---
, this value cannot be edited.
S11, Input voltage specifications
The dimmer processor continuously measures the voltage values for all
three phases of power supply. If this voltage measurement function fails,
(for example, if the AD-converter is defect) the processor can also use a
predefined input voltage value. This voltage value can be set individually
for all three phases in the
S11
menu.
L1/L2/L3 S11
230V 230V 230V
Open
•
Hit the
[ESC]
button until the main menu appears
•
Use
[PAGE]
or the encoder to scroll to the
M07
System
menu
•
[EDIT]
takes you to the most recently called system menu
Sxx
•
Use
[PAGE]
or the encoder to scroll to the
S11
L1/L2/L3
menu
Repeatedly pressing
[EDIT]
allows you to set the voltage values for Phases
Factory setting: all
230V
Reset to the factory settings
Processor settings can be reset to factory default.
Reset to ..
?
•
Open
•
Hit the
[ESC]
button until the main menu appears
•
Use
[PAGE]
or the encoder to scroll to the
M07
System
menu
– 20 –
FDX2000 Vers. 4.0.0