Implemented CANopen Objects
CAN-CBX_Pt100
Manual • Doc.-No.: C.3032.21 / Rev. 1.1
Page 59 of 120
8.9.6 Communication Cycle Period (1006
h
)
INDEX
1006
h
Name
Communication Cylcle Period
Data type
unsigned 32
Access mode
rw
Default value
0
ü
s
Value range of the parameter:
Value
Meaning
0
No transmission of SYNC messages
1...FFFFFFFF
h
Cycle time in microseconds