Connector Pin Assignment
Manual • Doc.-No.: C.3032.21 / Rev. 1.1
CAN-CBX_Pt100
Page 32 of 120
5.4 Conductor Connection/Conductor Cross Sections
The following table contains an extract of the technical data of the line connectors.
Interface
Power Supply
Voltage
24 V
[6]
CAN-
Connector
[7]
Temperature
Sensor
Interface
[8]
Connector type plug component
(Range of articles)
FKCT 2,5/..-
ST KMGY
FK-MCP
1,5/..-STF-
3,81
FMC
1,5/..- ST-3,5
Connection method
spring-cage
connection
spring-cage
connection
spring-cage
connection
Stripping length
10 mm
9 mm
10 mm
Conductor cross section solid min.
0.2 mm²
0.14 mm²
0.2 mm²
Conductor cross section solid max.
2.5 mm²
1.5 mm²
1.5 mm²
Conductor cross section stranded min.
0.2 mm²
0.14 mm²
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
1.5 mm²
1.5 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve min.
0.25 mm²
0.25 mm²
0.25 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve max.
2.5 mm²
1.5 mm²
1.5 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve min.
0.25 mm²
0.25 mm²
0.25 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve max.
2.5 mm²
0.5 mm²
0.75 mm²
Conductor cross section AWG/kcmil min.
24
26
24
Conductor cross section AWG/kcmil max
12
16
16
2 conductors with same cross section,
stranded, TWIN ferrules with plastic sleeve,
min.
0.5 mm²
n.a.
n.a.
2 conductors with same cross section,
stranded, TWIN ferrules with plastic sleeve,
max.
1 mm²
n.a.
n.a.
Minimum AWG according to UL/CUL
26
28
24
Maximum AWG according to UL/CUL
12
16
16
n.a. ... not allowed