Manufacturer Specific Profile Area
Manual • Doc.-No.: C.3032.21 / Rev. 1.1
CAN-CBX_Pt100
Page 100 of 120
8.11.3 Channel Enabled (2401
h
)
Index
Sub-
index
Description
Value range
Default
Data type
Access
mode
2401
h
0
Number_of_entries
4
4
unsigned 8
ro
1
channel_enabled_1
false, true
-
boolean
ro
2
channel_enabled_2
false, true
-
boolean
ro
3
channel_enabled_3
false, true
-
boolean
ro
4
channel_enabled_4
false, true
-
boolean
ro
Description of the variable channel_enabled_x (x = 1...4):
If a sensor has been detected for the measuring channel, this variable returns the “actual value”of the
object “AI_Operating_mode_x” (object 6112
h
). It indicates if the corresponding channel is active.
With object 6150
h
“AI_status_x” it can be determined if a sensor has been detected.
Value range:
channel_enablesd_x
Binary value
Meaning
false
0
A/D-converter channel is off
(AI_operation_mode_x = 0)
true
1
A/D-converter channel is on
(AI_operation_mode_x = 1)