4.2.2 CAN Connector (X400)
Device Connector:
Phoenix-Contact MC 1,5/5-GF-3,81
Line Connector:
Phoenix-Contact FK-MCP 1,5/5-STF-3,81, spring-cage connection,
Phoenix-Contact order no.:1851261 (included in the scope of delivery)
For conductor connection and conductor cross section see page 30.
Pin Position:
Pin-Assignment:
(device connector with labelling)
Labelling
Signal
Pin
G
CAN_GND
1
L
CAN_L
2
Sh
Shield
3
H
CAN_H
4
•
-
5
Signal description:
CAN_L, CAN_H ...
CAN signals
CAN_GND ...
reference potential of the local CAN physical layer
Shield ...
pin for line shield connection (using hat rail mounting direct contact to the
mounting rail potential)
- ...
not connected
Recommendation of an adapter cable from 5-pin Combicon (here line connector FK-MCP1,5/5-
STF-3,81 with spring-cage-connection) to 9-pin DSUB:
T he 9 -p in DSUB
connector is assigned
according to CiA 102