HOW TO OPEN THE
CABINET
Unpack the exchange cabinet.
Check that everything has been received according to
the delivery note and that nothing has been damaged
during the transport.
The cabinet cover is latched. To open reach inside the
center cable duct from below and push lever up gently
to unlock then remove the cabinet’s front cover. For
details of the bottom view of cabinet see page 8.
Overall dimensions of the cabinet:
•
400 x 500 x 155 (H x W x D in mm).
4
INSTALLATION
The PBX can be delivered as a customer configured
unit or the add-in boards can be delivered separately.
The cabinet is always equipped with a power supply,
suitable for the local mains. Please check the label
stating the permitted mains voltage. The cabinet is to
be mounted on an indoor wall. A mains outlet must be
provided near the equipment and shall be easily
accessible. Connection to earth (refer to 4.2) is
necessary for safe operation to discharge lightning
strikes. The premises shall comply with the following
prerequisites:
•
The air shall be free from dust and smoke
•
Environmental conditions according to
ETS 300 019 (1-4) (Temperature shall be
b 5
°
C and +40
°
C and relative humidity
may vary between 15% and 80%)
•
The PBX shall not be exposed to direct sunlight
4.1
Mounting of the cabinet
Attach the proper label at the bottom of the cabinet
before hanging up the cabinet (refer to section 4.2 on
page 7 for the position). The label must comply to the
SMPS installed and the local mains voltage level.
The cabinet’s wall mounting plate is located on the rear
of the cabinet during transport. Take into consideration
the normal working height above the floor (about 1.30
m to the lower edge of the cabinet) and leave enough
room for access on both sides of the cabinet. To pull
out the cabinet’s wall mounting plate remove the screw
C below the swivel shelf (refer to next page). Then
position the mounting plate where you want to mount
the cabinet, mark and drill three 8 mm holes. Insert the
enclosed wall plugs and screw tight the cabinet’s wall
mounting plate.
Lift latch to release the cabinet cover
Then remove the cabinet cover.
1
2
2
1
businessphone
TOP
Screw hole for screw (C)
wall mounting plate
to hold
figure: wall mounting plate
during transport