54(57)
Date
Rev
Documentnumber
Prepared
Doc respons/Approved
Checked
File/Reference
1999-07-15
V
1531-BDV 113 08 Uen
INSTALLATION INSTRUCTION
Subject responsible
9.2
External MDF SXK 106 4139/1
Unpack the MDF cabinet and remove its front cover.
Mount the MDF cabinet on its designated position.
Take into consideration the normal working height
above the floor (about 1.30 m to the lower edge of the
MDF cabinet) and the length (1.5 m) of prefabricated
cable
TSR 902 0444/1.
Overall dimensions
of the MDF cabinet: 295x184x68 (HxWxD in mm).
9.3
Line network
Place the cables according to the figure.
Secure the cables to the MDF cabinet with the adhe-
sive anchors and cable fastener.
NOTE:
There must be a connection to earth for the
MDF cabinet when surge protectors are
installed.
147 mm
228 mm
Mounting of MDF cabinet
Mark mounting holes for MDF cabinet
Loosen cover only by hand force
1
(there are no holding screws)
2
Drill and insert plugs
3
(Use enclosed screws and plugs)
Mount MDF cabinet and screw it
4
securely into position
Cables from
line network
Earth
Alternative
of cables to
connections
board
Alternative
connections
of cables from
line network
connection
Primarily intended
for trunkline use
Cable for board
connection:
TSR 902 0444/1
(with surge protectors)