22(57)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved
Kontr/Checked
Tillhör/Referens-File/Reference
1999-07-15
V
1531-BDV 113 08 Uen
INSTALLATION INSTRUCTION
Faktaansvarig - Subject responsible
5.10.1
Paging connection
The figure shows how to connect the paging equipment Ericall Contactor with 2 wire speech. The PBX sends paging
information to paging system (pin 6A18) using M1 contact, and information about ’paging in progress’ or ’paging
equipment not present’ is received on the E1-wire (pin 6C18) from the paging equipment.
Applies for switches 109, 209, 309 and 409.
Figure showing Paging equipment and 2-wire speech with ’loop connection’ of the E&M-wires.
1
2
3
on
S6 S7 S8
This switch setting is used for
signalling on E1 and M1.
Switch settings
S7
DSLA
C
M1
E1
M0
E0
-48V
0V
-48V
0V
E1
M1
E0
M0
6A18
6A20
6C18
6C20
0V
0V
S5
Z
M1
autom. 2/4wire
4A18
4A20
PBX
LA
LB
Paging equipment
0V
Detector
Detector