5(9)
Datum -
Date
Rev
Nr -
No.
Uppgjord
(även faktaansvarig om annan)
-
Prepared
(also subject responsible if other)
Dokansv/Godkänd -
Doc respons/Approved
Kontr -
Checked
File
1997-06-18
A
1531- DBC 210 01 Uen
INSTALLATION INSTRUCTIONS
Figure: 7-3.
Mounting of hook
7.5
Post installation measures
Verify that a call can be established from and to the DTS.
8
Installation of option unit DBY 410 02
Make necessary arrangements to avoid electrostatic discharges:
•
Disconnect the telephone set from the exchange
•
Avoid if possible to touch the contacts
•
Break off the blinder covering the contact C4.
•
Connect the cable P1 from DBY 410 02 to the contact C4 on the telephone.
•
Insert DBY 410 02 to its place in the bottom of the telephone. Secure it with the screw SCR 1.
•
Remove the blinder covering the connectors.
•
Move the handset cord from the DTS to the jack J1 marked HANDSET.
Note: When using DBY 410 02 the handset connector on the DTS will be disabled.
With the DBY 410 02 mounted, the telephone must be wall mounted using extra spacers.
Spacers, with a thickness > 22 mm, have to be mounted between the telephone and the wall.
Position for hook:
Wall mounting
180