3(6)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved
Kontr/Checked
Tillhör/Referens-File/Reference
1993-11-09
C
1531-RPM 603 339 Uen
INSTALLATION INSTRUCTION
Faktaansvarig - Subject responsible
These components are necessary to get the
temperature function:
•
AUX board ROF 157 5119 or/and CPU-D board
ROF 157 5118
•
(cable TSR 902 0444)
•
Tools for mounting of temperature sensor on the
wall.
•
Tools for connecting the sensor cable to the
connection block in the MDF.
•
Cable kit RPM 603 339/1 which contains:
•
cable with temperature sensor
•
wood screw
•
MOLEX connector
(not used in ASB 150 02)
Central software release R1 does NOT support more
than one sensor. This sensor must be installed as
sensor 1 connected to the CPU-D.
2
FUNCTIONALITY
The temperature is displayed on the digital phones
with display. The temperature trend, increasing or de-
creasing, is indicated by” ^” for increasing and “v” for
decreasing. Please note that the indication of tempera-
ture trend, for the first 30 minutes after installation may
not be correct (while reference values are being re-
corded).
2.1
ASB 150 01
2.1.1
Programming
No commands is needed to get the temperature indi-
cation. The temperature indication is automatically
turned on after the sensor is connected to ELU-A10,
and turned off after disconnection of the sensor.
Please note that only one temperature sensor is to be
installed for one system.
2.1.2
Possible revisions for temperature
function
These revisions are necessary for ROF 157 50 25/X to
get the temperature function:
/2,3,4,5,7,8,11,12 R2A/A or higher revision
/6,10 R3A/A or higher revision.
2.2
ASB 150 02
2.2.1
Programming
In central software release R1 there is no program-
ming necessary.
In forthcoming central software releases there will be
some programming required to select sensor and how
to display its data.
Programming of these features will be done in the
RASC support system.