![Ericsson BDV BS 101 01 Скачать руководство пользователя страница 158](http://html.mh-extra.com/html/ericsson/bdv-bs-101-01/bdv-bs-101-01_installation-instructions-manual_2423246158.webp)
8(8)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved
Kontr/Checked
Tillhör/Referens-File/Reference
1999-07-15
C
1531-BML BS 101 01 Uen
INSTALLATION INSTRUCTION
Faktaansvarig - Subject responsible
6
ELECTRICAL CONNECTION
The following supply cables are required for a complete
installation of an exchange with battery backup:
a
DC power supply cable from the power supply to the
exchange.
b
Battery power cable with 6-pin connector and a 4-pin
connector. This cable is part of the battery-cable-set
NTM BS 101 28
c
Common I/O cable e.g. TSR 901 0472/3 or
TSR BS 902 0001/xxxxx
d
2-pole power supply alarm cable TRE 990 112/3000 or
the cable supplied with cable set NTM BS 101 28
e
Mains cord (see 1531-BDV 101 05 sect. 8.1). This cord
set must be approved by the local authorities in the
country where it is to be used. The plug (type IEC 320
C13) must be right angular for the connection to the
power supply unit and moulded to the cord.
7
ACCESSORIES
7.1
Fuse
ERICSSON ordering number NGH 258 03/630.
7.2
Batteries
The batteries for this exchange must comply to:
ERICSSON product No.
BKC BS 101 01/1
VOLTAGE:
12 V
CAPACITY:
minimum 2 Ah
TYPE:
maintenance-free
SIZE:
L=178 mm H=60 mm W=34 mm
WEIGHT:
approx. 0,93 kg
Representative types:
VARTA
CF 12-2,0
Onr.56 220 706 063
Hitachi
HP2-12
MDF
EXCHANGE
PO
WER SUPPL
Y
BA
TTER
Y CABINET
a
b
c
d
e