36(46)
Date
Rev
Documentnumber
Prepared
Doc respons/Approved
Checked
Reference
1998-05-29
L
1531-BDV BS 101 01 Uen
INSTALLATION INSTRUCTION
Subject responsible
The BSs can be mounted vertically or horizontally. Mount the BSs at places and positions as determined in the system
configuration plan. The BS must be placed such that it is not facing large metal objects such as large heating pipes,
machines.
Fixing the mounting bracket to a wall
Fix the mounting bracket (see figure below) to the wall as follows:
1.
Hold the mounting bracket with its flat side against the wall such that the text ‘TOP’ is the right way up,
and mark the two holes. The minimum distance between the upper hole and the ceiling or any object
above the BS must be as least 65 mm. If the distance is less than 65 mm, the BS cannot be slid onto
the bracket.
2.
When using wall plugs, take a
∅
6 mm drill and drill the two holes and insert the included wall plugs.
3.
Position the mounting bracket with its flat side to the wall and fasten it with the two included
∅
3.5 mm
screws.
Fixing the mounting bracket to a pole or beam
The mounting bracket can be fixed to a pole (diameter
≥
45 mm) or a beam (wider than 50 mm) by means of a strap
or flexible metal band less than 30 mm wide. Fix the mounting bracket to a pole or beam such that the text ‘TOP’ is
right way up. The strap or flexible metal band must be purchased locally.
TOP
≥
65 mm
Ceiling
Tied wrongly