INSTALLATION INSTRUCTION
Faktaansvarig - Subject responsible
1
GENERAL
This document describes how to install the water proof
temperature sensor(s) RPM 603 339.
The temperature sensor(s) may be situated outdoor to
measure the outdoor temperature.
The document describes the connection to both
ASB 150 01 and ASB 150 02.
1.1
ASB 150 01
The sensor is connected to ELU-A10 by a 10m cable,
and is attached to the front of ELU-A10 (4*3) by a
molex connector. The molex connector is not mounted
in order to cut/extend the cable to suitable length.
These components are necessary to get the
temperature function:
•
ELU-A10 (please see section 2.1.2 for
demanded revision on PCB (revision R3 or
higher on TVM 115 5025)
•
Tools for cable stripping and mounting of
temperature sensor on the wall
•
Cable kit RPM 603 339/1 which contains:
•
Molex connector
•
cable with temperature sensor
•
wood screw
1.2
ASB 150 02
The sensor(s) is connected to the ASB 150 02 system
through a 10m cable.
For connection of the temperature sensor(s) to the
CPU-D or AUX board, the standard i/o cable
TSR 902 0444 may be used.
This cable will carry all feature connections from the
CPU-D board to the MDF (Main Distribution Frame).
Should this system already be using some of the
system features (music input, alarm output, alarm
input or temperature sensors) there is already such a
cable installed.
It is possible to connect 3 external temperature
sensors to either board type.