27(57)
Date
Rev
Documentnumber
Prepared
Doc respons/Approved
Checked
File/Reference
1999-07-15
V
1531-BDV 113 08 Uen
INSTALLATION INSTRUCTION
Subject responsible
wise data is lost if printer is OFF. The range of the in-
terface is up to 1200m.
Several converters may be used but with the following
successful tests were accomplished:
IC-485SI from ARP DATACON and
232<->485/422 Converter Plus IC-109AE from Black
Box Corp.
5.12.1
Feature Enabling Control Unit (FECU)
Connecting this plug activates the appropriate applica-
tions and features as ordered depending on the FECU
index number. If no plug is connected only a limited
Version 4.0 system functionality is available. The indi-
ces 2 to 10 always include the Basic Version 4 func-
tionality (index 1).
For detailed information of the features enabled by the
different FECUs refer to
5.13
ELU-C (ROF 157 5115/1)
This board is used to connect the DBC 7xx series to
the ASB 150 02 system.
FECU number
Functionality Version 4.0
KDU BS 130 07/1 Basic Version 4.0 functionality
KDU BS 130 07/2 + std. digital networking for max.
32 interfaces
KDU BS 130 07/3 + std. digital networking
KDU BS 130 07/4 + full. digital networking for max.
32 interfaces
KDU BS 130 07/5 + full. digital networking
KDU BS 130 07/6 + full. digital networking, 4
interfaces and CTI
KDU BS 130 07/7 + std. digital networking for max.
32 interfaces and CTI
KDU BS 130 07/8 + std. digital networking and CTI
KDU BS 130 07/9 + CTI + full. digital networking for
max. 32 interfaces
KDU BS 130 07/10 + CTI + full. digital networking for
unlimited number of interfaces
Connection field 6 at front of ELU-C
1
1
10
10
LB0
LA0
LB1
LA1
LB2
LA2
LB3
LA3
LB4
LA4
LB5
LA5
LB6
LA6
LB7
LA7
LB8
LA8
LB9
LA9
Line wires for
connection to
extension equipment
6
*
1
6
*
3