Содержание 12big Rack Serial 2

Страница 1: ...12big Rack Serial 2 Quick Install Guide...

Страница 2: ...ll supply power for complete isolation In order to comply with applicable safety emission and thermal requirements no covers should be removed and all bays must be populated with plug in modules The p...

Страница 3: ...ber of units installed in the rack When addressing these concerns consideration should be given to the electrical power consumption rating shown on the nameplate The electrical distribution system mus...

Страница 4: ...ibution unit with a UPS Host computer with the correct firmware BIOS and drivers Contact your supplier for the correct software levels Before setting up your enclosure ensure you have the following SA...

Страница 5: ...nspect the packaging for crushes cuts water damage or any other evidence of mishandling during transit If any damage appears present for future reference photograph the packaging before opening 2 Unpa...

Страница 6: ...the System into a Rack 1 Remove the Rack Mounting Rail Kit from the Accessory Box and check for damage 2 Attach left and right chassis slides to the enclosure sides using 8 M3 x 4 buttonhead screws se...

Страница 7: ...g the washers and screws supplied The screws should be left loose b Extend rail to fit between the front and rear rack posts c Attach the bracket to the front rack post using the washers and screws su...

Страница 8: ...LaCie Quick Install Guide 7 e Return the enclosure to the fully home position Figure 4 Mounting the System into a Rack...

Страница 9: ...for several min utes for the update and then reboot of the system When using this product as an expansion chassis for the LaCie 12big Rack Network software should be updated using the appropriate met...

Страница 10: ...LaCie Quick Install Guide 9 Figure 6 Dual Host Multiple Enclosures...

Страница 11: ...wer on the storage system by connecting the power cables to the power distribution unit PDU powering on the PDU mov ing the PCM switches to the ON position and then powering on the host system Figure...

Страница 12: ...EDs Status I O Module Fault Amber I O Module OK Green Host Port Activity Green I O Module OK Off On X I O Module Fault On Off X No Host Port Connection X X Off Host Port Connection No Activity X X Off...

Страница 13: ...power any PCM Off Off Off Off No AC power this PCM only Off Off On On AC present PCM On OK On Off Off Off PCM fan fail Off On Off Off PCM fault over temp over voltage over current Off On On On Standby...

Страница 14: ...d Off Off None Drive installed and operational On Blink with acitivity or startup X None SES device identity set On Flash 1s on 1s off None SES device fault bit set On On Logical fault Amber Power con...

Страница 15: ...lt Am ber LED Diplay Associ ated LEDs Alarms Status On Off Off X Aux present overall power failed or switched off On On X X Single beep then double beep Ops panel Power On 5s test state On Off Off X P...

Страница 16: ...us failure inter SBB comms EBOD VPD configuration error On Flash X X PCM fault LEDs fan fault LEDs Unknown invalid or mixed PCM type installed or I2C bus failure PCM comms On X On X Array in failed or...

Страница 17: ...o B1 Via dei Missaglia 97 20142 Milano info it lacie com Elecom Japan http www lacie jp support LaCie Nordic Sweden Denmark Norway Finland Sveav gen 90 5tr 113 59 Stockholm Sweden info nordic lacie co...