Appendix B
List of Configurations by Model
S5U1C17001Y23 Multi-Programmer
Seiko Epson Corporation
43
System Manual (Rev. 1.1)
Table B.4 List of Configurations by Model (4)
Model name Erase/Write Program
User Program
Available
ICDmini
hardware
version
Available
ICDmini
firmware
version
ICDmini DIP
switch (SW8) &
FLASH VCC OUT
connection
*3
Remarks
File (1)
*1
Erase
Routine
Address
(2)
Write
Routine
Address
(3)
Time out
(4)
*2
Comment (5)
Start
Block
No. of
Erase
(7)
End
Block
No. of
Erase
(8)
Flash
Memory
Top
Address
(9)
S1C17W18 fwr17w18_2kbv11.saf
0x48
0x7c
60
"-v7.5-7.5"
0
0
0x8000 2.0
3.3 or later
ON
Connect VPP
※7
fwr17w18_16bv11.saf
0x48
0x7c
60
0
0
0x8000 1.0, 1.1, 2.0 3.3 or later
OFF
No connection
※8
S1C17W22 fwr17w22v11.saf
0x48
0x7c
60
"-v7.5-7.5"
0
0
0x8000 2.0
3.3 or later
ON
Connect to V
PP
S1C17W23 fwr17w23v11.saf
0x48
0x7c
60
"-v7.5-7.5"
0
0
0x8000 2.0
3.3 or later
ON
Connect to V
PP
Note:
*1 The files are stored in the C:\EPSON\C17GangWriter\mcu_model folder (default) by model.
*2 Time-out time (Although any time can be set, the table lists the maximum time. )
*3 This column shows the ICDmini DIP switch (SW8) setting and whether the FLASH VCC OUT pin of the flash memory programming power supply connector must be connected to the V
PP
pin
of the target MCU or not.
*4 Settings for the model with 8.1 to 16.0 MHz operating frequency range
*5 Settings for the model with 4.0 to 8.0 MHz operating frequency range
*6 Settings for the model with 16.1 to 24.0 MHz operating frequency range
*7 When the FLASH VCC OUT pin output of the ICDmini Ver. 2.0 is used as the flash memory programming power supply
*8 When the voltage regulator/booster embedded in the target MCU is used as the flash memory programming power supply