Appendix A
Gang Writer Dynamic Link Library
S5U1C17001Y23 Multi-Programmer
Seiko Epson Corporation
31
System Manual (Rev. 1.1)
A.2.6 GetStatus
•
Function
Returns the status of the current operation.
•
Format
long GetStatus (long IcdDeviceNumber, long* ErrorAddress);
•
Arguments
IcdDeviceNumber: ICDmini ID number (0 to 999)
ErrorAddress:
The error occurrence address is stored.
ResetTarget:
Fixed at 0.
CheckTargetConnection: Fixed at 0.
StartErase:
Erase start address
StartWrite:
Error occurrence address
StartVerify:
Error occurrence address
•
Return values
OK
OPERATION_TARGET_CONNECTION
OPERATION_TARGET_RESET
OPERATION_ERASE
OPERATION_WRITE
OPERATION_VERIFY
ERROR_PARAMETER
ERROR_TIMEOUT_TARGET_CONNECTION
ERROR_TIMEOUT_TARGET_RESET
ERROR_TIMEOUT_ERASE
ERROR_TIMEOUT_WRITE
ERROR_TIMEOUT_VERIFY
ERROR_ICD_CONNECTION
ERROR_TARGET_CONNECTION
ERROR_TARGET_RESET
ERROR_ERASE
ERROR_WRITE
ERROR_VERIFY