6. Gang Writer Configuration
S5U1C17001Y23 Multi-Programmer
Seiko Epson Corporation
19
System Manual (Rev. 1.1)
Table 6.4.2 List of STATUS Massages
STATUS message
Description
(G00) COMPLETE
Loading FLS and the user program data to the ICDmini has completed
successfully.
(G10) FLS ERASE
FLS storage area is being erased.
(G11) FLS LOAD xxx%
FLS is being loaded (0% to 100%).
(G12) FLS VERIFY
FLS storage area is being verified.
(G13) USER ERASE
User program data storage area is being erased.
(G14) USER LOAD xxx%
User program data is being loaded (0% to 100%)
(G15) USER VERIFY
User program data storage area is being verified.
(G21) FLS TIMEOUT ERROR
A communication time-out has occurred during loading FLS to the ICDmini.
(G22) FLS FILE OPEN ERROR
The FLS file cannot be opened.
(G23) FLS FILE FORMAT ERROR
The FLS file format is invalid. (It is not a Motorola format.)
(G24) FLS FILE SIZE OVER
The FLS file size exceeds 8KB.
(G25) FLS FILE ADDRESS OVER
The address in the FLS file exceeds the 24-bit range.
(G26) FLS LOAD VERIFY ERROR
An error has occurred during verify check after loading FLS to the ICDmini.
(G27) FLS UNEXPECTED ERROR
Unexpected error has occurred during loading FLS to the ICDmini.
(G31) USER TIMEOUT ERROR
A communication time-out has occurred during loading the user program
data to the ICDmini.
(G32) USER FILE OPEN ERROR
The user program data file cannot be opened.
(G33) USER FILE FORMAT ERROR
The user program data file format is invalid. (It is not a Motorola format.)
(G34) USER FILE SIZE OVER
The user program data file size exceeds 4MB.
(G35) USER FILE ADDRESS OVER
The address in the user program data file exceeds the 24-bit range.
(G36) USER LOAD VERIFY ERROR
An error has occurred during verify check after loading the user program
data to the ICDmini.
(G37) USER UNEXPECTED ERROR
Unexpected error has occurred during loading the user program data to the
ICDmini.
(G99) ICD COMMUNICATION ERROR
Communication with the ICDmini cannot be established.
Display message number classification
(G00): Loading has completed successfully.
(G1x): Data is being loading.
(G2x): An error has occurred during loading FLS.
(G3x): An error has occurred during loading the user program data.