6. Gang Writer Configuration
18
Seiko Epson Corporation
S5U1C17001Y23 Multi-Programmer
System Manual (Rev. 1.1)
Table 6.4.1 List of Error Messages
Error Message
Description
Please check all items.
No target system to be programmed is found. Make sure that the ICDmini is
connected to the PC correctly and then click on the [DETECT] button to get
the connected ICDmini recognized before clicking the [LOAD START]
button.
Over useful range. Check ID No.
One or more values entered in the [ID No.] fields exceed the effective
range. The ID No. must be within the range from 0 to 999.
There are the same as “ICDmini Serial No.”
item two or more.
Two or more ICDminis have the same serial number. Refer to “5.4
Confirming ICDmini Hardware Version and Programming Serial Number”
and reconfigure the ICDminis with a unique serial number.
There are the same as “ID No.” item two or
more.
Two or more [ID No.] fields have the same number entered. Change them
to a unique number.
Please set load parameter information.
The [Parameter File] field is empty and the parameters have not been
configured in the [Set Load Parameter] dialog box yet. Refer to “6.2 Setting
Gang Writer Parameters” and fill in the parameter fields.
Can not found Parameter file.
The parameter file specified in the [Parameter File] field cannot be found.
Use the [Browse] button to specify the parameter file. Refer to “6.4 Loading
Program to ICDmini.”
Parameter file error.
There is an error in the contents of the parameter file. Refer to “6.2 Setting
Gang Writer Parameters” and correct the illegal parameter value.
Following characters of parameter file are
not allowed to used.
/;,*?<>|"
One of the characters shown below is included in the parameter file name.
/ ; , * ? < > | ”
Do not use these characters for the parameter file name.