3-26
REV.A
3.2.17. Removing the CD10DR Board Assembly
Prerequisite condition: 3.2.3/3.2.7/3.2.8
Figure3- 35EMP-7300 CD10DR board
1. Remove five hex stud screws fixing the CD10DR board.
Screw: hexagon screw P/N1033069 (mounting torque: 6.0kg.cm = 5.2lb.inch)
2. Disconnect the connectors from CN 100.
3. Disconnect the FPC cables from CN 700/800/900.
4. Pull it straight up.
Figure3- 36 EMP-7300 CD10DR board
Caution:
Before disconnecting the FPC cable from the connectors, softly pull each connector
straight up to unlock it.
LV Thermister
CN103
CN104
(Adjustment)
CN700
CN800
CD10DR
board
CN900
CN100(fuse)
CN700
CN100
CN800
CN900
Hex stud screws
Hex stud screws