manualshive.com logo in svg
background image

 

  

NEC Display Solutions Europe GmbH

                  

NP500W Installation Guide 

Ceiling Mounted and Desktop 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev 1.1 

www.nec-display-solutions.com

                                                                                 

            NP500W 

 

                             Page 1 of 6 

 

Contents 

Product Description, Lens Specs, Notes and Formulas 

 

 

Pg  1 

Diagrams 

Distance 

Charts 

          Pg 2 

Cabinet Dimensions   

 

 

 

 

 

 

 

 

 

 

 

Pg 3-4 

Ceiling 

Mount 

Dimensions           Pg 5 

Input 

Panel 

and 

Control 

Codes 

         Pg 6 

 

 

Product 

Description                              

Type:   

 

 

 

3 panel LCD projector,   

 

 

 

 

 

Dimensions:  308 mm (W) x 93,5mm (H) x 262mm (D)   

      0.59” 

p-Si 

TFT 

w/MLA       Weight:  2,98 

Kg    

Resolution:   1280 

800          Brighness: 

 NP500W 

– 

3000 

Lumens 

 

Fan Noise:       

 

35 dB / 29dB @ 1 meter   

 

 

 

 

 

Power Consumption: NP500W = 325W (max)   

 

 

 

 

 

BTU’s:  

 

1007 BTU/hour 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lens Specifications                                                           

Throw Ratio:   

1.4 – 1.6:1  (for 100” diagonal)     Focal 

Length: 

 

 17.7mm 

– 

21.2mm    

Offset Angle:   

7.6° - 9.2° (for 100” diagonal)     F/#:    1. 

2.0 

       

 

Screen 

Sizes: 

 21” 

300” 

diagonal 

(4:3) 

      Manual 

Focus/Manual 

Zoom 

           

 

 

 

 

 

 

 

 

 

Notes                                                                     

ƒ

 

For screen sizes not indicated on the projection tables, use the formulas below. 
If the figures on the tables do not match the results of formulas, use the figures in the table. 

 

All calculations are based on a 4:3 aspect ratio. 

 

Distances may vary 

±

5%. 

 
 

Formulas                                                                   

The Projection Formulas use the image width for calculation. For proper projection placement, determine the image width 
for the desired screen size. Use the Screen Formulas below to calculate all screen dimensions. Plug in the width for “W” in 
the Projection Formulas. 
Refer to the diagrams and charts for popular screen sizes on page 2: 

 

Definitions:   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16:10 Screen Formulas: 

W = Image Width  

 

 

 

 

 

 

 

 

 

 

 

 

 

W = H x 16/10 

Image 

Height 

(size) 

            H 

10/16 

B = Vertical distance between lens center and screen center   

 

Screen Diagonal = W x 18.868/16 

C = Throw distance 
D = Vertical distance between lens center and screen top 
 

 (screen bottom for desktop application) 

 

Projection Formulas: 
B

 

0.232W            

C

 (wide) = 1.3702W – 1.173 

(tele)

 

 = 1.6526W – 1.176 

D

 = 0.097W 

α

 (wide) = tan¯¹ (B/C(wide)) 

α

 (tele) = tan¯¹ (B/C(tele)) 

 
 
 
 

Содержание NO500W

Страница 1: ... screen sizes not indicated on the projection tables use the formulas below If the figures on the tables do not match the results of formulas use the figures in the table All calculations are based on a 4 3 aspect ratio Distances may vary 5 Formulas The Projection Formulas use the image width for calculation For proper projection placement determine the image width for the desired screen size Use ...

Страница 2: ...dth W H eight H m m m m m m m m 21 59 1 829 1 1 43 424 2505 3021 233 7 1 93 0 81 3 1 981 1 245 460 271 3 3273 233 7 1 93 0 965 21 08 1 321 489 2887 3483 233 7 1 93 0 2591 21 84 1 372 507 2992 3609 233 7 1 93 0 281 9 2388 1 499 554 3270 3945 233 7 1 93 0 2870 2438 1 524 566 3340 4029 233 7 1 93 0 31 24 2642 1 651 61 3 361 8 4364 233 7 1 93 0 31 75 2692 1 676 625 3688 4448 233 7 1 93 0 3734 31 75 1 ...

Страница 3: ...ions Europe GmbH NP500W Installation Guide Ceiling Mounted and Desktop Rev 1 1 www nec display solutions com NP500W Page 3 of 6 Cabinet Dimensions The following drawings show the cabinet dimensions Dimensions are in mm ...

Страница 4: ...Europe GmbH NP500W Installation Guide Ceiling Mounted and Desktop Rev 1 1 www nec display solutions com NP500W Page 4 of 6 Cabinet Dimensions continued The following drawings show the cabinet dimensions Dimensions are in mm ...

Страница 5: ...urope GmbH NP500W Installation Guide Ceiling Mounted and Desktop Rev 1 1 www nec display solutions com NP500W Page 5 of 6 Optional Ceiling Mount Dimensions Model NP08CM The following drawings show the ceiling mount dimensions ...

Страница 6: ...H 13H SOUND MUTE ON 02H 12H 00H 00H 00H 14H SOUND MUTE OFF 02H 13H 00H 00H 00H 15H PROJECTOR INFORMATION REQUEST 00H BFH 00H 00H 01H 02H C2H ERROR STATUS REQUEST 00H 88H 00H 00H 00H 88H INFORMATION REQUEST 03H 8AH 00H 00H 00H 8DH Note Contact your NEC rep for codes not listed Cable Connection Communication Protocol Baud Rate 38400 bps Data Length 8 bits Parity No Parity Stop Bit One Bit X on off N...

Отзывы: