4-6
REV.A
Figure4- 5
Continued from page 4-5
Replace power cable.
Connect AC cable to the other
outlet.
Does AC power is applied to
the connector on the Power
supply unit.?
Does AC power is applied to
the connector on the Power
supply unit.?
Replace the power supply
unit.
NO
YES
YES
NO
A
Go to start
< Lamp indication table >
Condi
tion
Lamp
indicator
Operation
indicator
Meanings
1
OFF
Orange
System initialization.
2
Green-blink
Green
Warm up operation.
3
Green
Green
Operating.
4
Orange-blink
Orange
Cool down operation.
5
OFF
Orange
Standby.
(Cool down complete)
6
OFF
OFF
Power off condition.
7
-
Red or
Orange-blink
Over heat condition.
8
-
Red-blink
Circuit malfunction.
9
Orange and Red
-
Lamp timer exceed 1900 hours.
10
Red
-
Lamp life is finished.
11
Red-blink
-
Lamp or Power supply problem.
< Suspect cause reason >
(1)Stop at the condition 1 or 8.
-
CD10MA
board, Driver board(Optical engine), Power supply unit.
(2)Stop at the condition 2.
-
CD10MA
board, Power supply unit, Lamp inner housing.
(3)Stop at the condition 4.
-Exhaust fan, Lamp Thermister,
(4)Stop at the condition 6.(Power on problem)
-AC input, Power supply unit(include interlock switch),
CD10MA
board,
Safety switch.
(5)Stop at the condition 7. (Sometimes occur during operation.)
-Air filter frame(dirt condition), Exhaust fan, Power supply unit,
CD10MA
board, Thermister(LV/PBS/Lamp)
(6)Stop at the condition 9 or 10.
-Lamp inner housing,, FC board.
(7)Stop at the condition 11.
-Power supply unit, Lamp inner housing.
Содержание EMP-7300
Страница 1: ...EPSON DATA PROJECTOR XGA Data Projector SERVICE MANUAL EMP 7300 EPSON ...
Страница 8: ...Chapter 1 Product general ...
Страница 16: ...1 8 REV A 1 3 CONNECTION 1 3 1 Connecting to a PC Figure1 13 Computer cable Attached Accessory Computer 1 ...
Страница 22: ...1 14 REV A Receptor board Figure1 33 Receptor board Receptor board Receptor board ...
Страница 29: ...Chapter 2 Theory of operation ...
Страница 65: ...Chapter 3 Disassembly and assembly ...
Страница 97: ...Chapter 4 Troubleshooting ...