![Epson EMP-7300 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/epson/emp-7300/emp-7300_service-manual_2419611036.webp)
2-7
REV.A
* The blower fan (connect to the CN622 on the CD10MA board) is built for exhausting
the heat generated in the power supply unit. The heat exhausted by the blower fan will
be exhausted outside by the exhaust fan which is connected to the connector CN 621
on the CD10MA board.
(3) Pin assignment on the CD10MA board connector CN 600
Table2- 3
CN600
Pin .No
Signal
1
+5V_S
2,3
+5V
4,5
3.3V
6,7
12V_F
8
PWDS
9
PWON
1 to 12
L GND
13,14
A GND
15
-12V
16
+12V
17
+22V
18
L GND
19
LPSTC
20
BACTA
Figure2- 8
PIN 20
PIN 1
CN600