3-6
REV.A
3.2.1 Removing the Lamp Inner Housing
Prerequisite conditions: None.
Warning:
The lamp unit is very hot immediately after it is in use and may cause burns if you
handle it carelessly. Before removing the lamp unit, make sure the temperature of
the lamp inner housing unit has cooled down.
Lamp cover
Screws
Figure3- 2
Screws
Lamp inner housing
Handle
Figure3- 3
1. Remove the lamp cover unit two fixing screws from the bottom of lower case.
Screw:-M4*7 B/Ni: P/N1038173 (mounting torque: 4.5 kg.cm = 3.9 lb.inch)
2. Remove two lamp inner housing fixing screws.
Screw:-M4*7 B/Ni: P/N1038173 (mounting torque: 4.5 kg.cm = 3.9 lb.inch)
3. Pull up the handle on the lamp inner housing and remove the lamp unit.
Caution:
When installing the lamp unit, take care not to touch the lamp's reflector with a hand
(to prevent the reflector from being contaminated).
Содержание EMP-7300