![Epson EMP-7300 Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/epson/emp-7300/emp-7300_service-manual_2419611059.webp)
2-30
REV.A
2.15 SENSOR / SWITCH
For user’s safety and safety operation of this projector (for prevention from
malfunction), the following devices listed the table *-* are installed in it.
Table2- 5 Sensor/switch
Name
Location/Type
Function/Use
Interlock switch
Push-switch on the power supply
unit
Power off, in opening the lamp
cover. (Power on is disabled.)
Safety switch
Thermal switch on the lamp outer
housing
Overheat protection for light
source lamp area. Power is shut,
temperature exceeds limitation.
Lamp house thermistor
On the lamp outer housing
(Thermistor)
Overheat protection for light
source lamp area. Power off,
temperature exceeds limitation
LV thermistor
On the prism duct (Thermistor)
Overheat protection for light bulb.
Power off, temperature exceeds
limitation.
Front temperature thermistor
On the side of the power supply
unit (Thermistor)
Overheat protection for power
supply unit. Power is shut,
temperature exceeds limitation.
Содержание EMP-7300
Страница 1: ...EPSON DATA PROJECTOR XGA Data Projector SERVICE MANUAL EMP 7300 EPSON ...
Страница 8: ...Chapter 1 Product general ...
Страница 16: ...1 8 REV A 1 3 CONNECTION 1 3 1 Connecting to a PC Figure1 13 Computer cable Attached Accessory Computer 1 ...
Страница 22: ...1 14 REV A Receptor board Figure1 33 Receptor board Receptor board Receptor board ...
Страница 29: ...Chapter 2 Theory of operation ...
Страница 65: ...Chapter 3 Disassembly and assembly ...
Страница 97: ...Chapter 4 Troubleshooting ...