Setup & Operation 6. Options
66
C12 Rev.3
6.3 Tool Adapter (ISO Flange)
Using the tool adapter, you can mount the end effector whose dimensions are designed for
the ISO flange to the C12 series Manipulators.
Parts included
Qty.
ISO flange
1
Flange
1
Pin
2
Hexagon socket head screw with low head M5
×
10
6
Hexagon socket head screw M5
×
15
4
Dimensions of ISO flange
4-M5 depth 12
(at 90
°
pitch)
depth 5
depth 4
To mount the ISO flange
(1) Press-fit the pin to the Arm #6 end flange.
Pin projection : 4 mm from the flange
Pin
(2) Align the pin and the pin hole on the flange, and then
mount the flange.
Hexagon socket head screw: 4-M5
×
15
Hexagon socket
head screw 4-M5×15
Flange
(3) Press-fit the pin to the installed flange.
Pin protrusion: 4 mm from the flange
Pin
(4) Align the pin and the pin hole on the ISO flange, and
then mount the ISO flange.
Hexagon socket head screw
with low head: 6-M5
×
10
ISO flange
Hexagonal socket head
screw with low head
6 M5×10
Содержание C12 Series
Страница 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Страница 2: ...Manipulator manual C12 series Rev 3 ...
Страница 8: ...vi C12 Rev 3 ...
Страница 14: ...Table of Contents xii C12 Rev 3 ...
Страница 16: ......
Страница 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Страница 83: ...Maintenance This volume contains maintenance procedures with safety precautions for C12 series Manipulators ...
Страница 84: ......
Страница 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Страница 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Страница 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Страница 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...
Страница 159: ...Maintenance 4 Cable Unit C12 Rev 3 145 ...