Maintenance 4. Cable Unit
C12 Rev.3
131
46.
Fix the Arm #1 cable fixing plate temporarily to the Arm #1 and
finely adjust the cable length.
Hexagon socket head cap bolts: 2-M4
×
10
Rough guide of temporary fixing: The plate should not move.
Notes for fine adjustment:
- No excess looseness or tension on the cables.
The cables should not be pressed strongly against the arm edge.
- The X021, X121, BR021, and CN3 connectors should reach
the end face of the Arm #1 when they are pulled out.
The cables should not be too long.
47.
Place a mark on the cables at the sleeve outlet on the base side.
48.
Fix the cable bracket (C1)-A on the near side so that the cable
positions do not change.
Hexagon socket head cap bolts: 2-M3
×
6
Tightening torque: 2.4
±
0.1 N·m
49.
Remove the Arm #1 cable fixing plate fixed temporarily, and fix
another cable bracket (C1)-B.
Removing Arm #1 cable fixing plate:
Hexagon socket head cap bolts: 2-M4
×
10
Fixing cable bracket (C1)-B:
Hexagon socket head cap bolts: 2-M3
×
6
Tightening torque: 2.4
±
0.1 N·m
A
B
Содержание C12 Series
Страница 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Страница 2: ...Manipulator manual C12 series Rev 3 ...
Страница 8: ...vi C12 Rev 3 ...
Страница 14: ...Table of Contents xii C12 Rev 3 ...
Страница 16: ......
Страница 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Страница 83: ...Maintenance This volume contains maintenance procedures with safety precautions for C12 series Manipulators ...
Страница 84: ......
Страница 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Страница 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Страница 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Страница 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...
Страница 159: ...Maintenance 4 Cable Unit C12 Rev 3 145 ...