Setup & Operation 5. Motion Range
C12 Rev.3
55
5.2.2 Motion Range Setting of Joint #2
Remove the mechanical stop installed as standard and install the adjustable mechanical stop
(J2). (Joint #2 standard motion range
−
135
°
to +55
°
)
Hexagon socket head cap bolt M10×35×2 bolts
Tightening torque
32.0 ± 1.6 N·m (326 ± 16 kgf·cm)
d
e
d
e
Angle (
°
)
−
125, +45
−
135, +55
Pulse(pulse)
−
9830500
+3538980
−
10616940
+4325420
Adjustable mechanical stop (J2)
Applied
Applied (standard)
5.2.3 Motion Range Setting of Joint #3
Remove the mechanical stop installed as standard and install the adjustable mechanical stop
(J3). (Joint #3 standard motion range
−
61
°
to +202
°
)
Hexagon socket head cap bolt M6×15×2 bolts
Tightening torque
13.0 ± 0.6 N·m (133 ± 6 kgf·cm)
f
g
f
g
Angle (
°
)
−
51, +192
−
61, +202
Pulse(pulse)
−
3342336
+12582912
−
3997696
+13238272
Adjustable mechanical stop (J3)
Applied
Applied (standard)
Содержание C12 Series
Страница 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Страница 2: ...Manipulator manual C12 series Rev 3 ...
Страница 8: ...vi C12 Rev 3 ...
Страница 14: ...Table of Contents xii C12 Rev 3 ...
Страница 16: ......
Страница 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Страница 83: ...Maintenance This volume contains maintenance procedures with safety precautions for C12 series Manipulators ...
Страница 84: ......
Страница 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Страница 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Страница 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Страница 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...
Страница 159: ...Maintenance 4 Cable Unit C12 Rev 3 145 ...