5.6 Error messages
Error messages are shown on the display in plain text. When an error mes-
sage appears, the heating period in progress is interrupted.
In a multi-cabin installation, the malfunction is shown in the status
bar of the cabin overview. Error message details are displayed in the
affected cabin.
!
Error – error message
Reason
Solution
Display is blank
No power.
Check fuses.
Switch-off switch is switched off.
Check that the switch is in the correct posi-
tion.
No connection between the control
panel and the power unit.
Check the cable for a secure connection.
Temperature sensor fault
No connection to the temperature
sensor.
Check the cable and connections.
Sensor is defective.
Replace the sensor.
No heat.
No connection.
Check the cable and connections (broken
cable, loose connection, etc.).
Safety temperature limiter triggered.
Safety temperature limiter may have been
triggered by overheating in the cabin. Rec-
tify the reason for overheating.
Replace the safety temperature limiter fuse.
Water shortage
Not enough water in the vaporiser.
Refill water.
Install automatic filling, if necessary.
Malfunction when automatically filling
water.
Check water supply. Clean the filter at the
water supply connector if necessary.
No water supply, water inlet valve
clogged, blocked, or defective.
Clean the water inlet valve and check that it
functions properly. Replace the water inlet
valve if necessary.
No bus communication
Faulty connection to the control panel. Check the cabling between the control
panel and the power unit.
Restart the control unit.
Contact technical support.
Other errors
Software error.
Restart the control unit.
Contact technical support.
Cabin image is displayed only in
grey
Incorrect bus configuration.
Power unit not detected.
Check the cabin address.
Power unit is connected to the wrong
jack in the control panel.
Check the cabin address and connection in
the control panel.
Multiple power units are programmed
with the same address.
Check the cabin addresses. See
6.3 Programmierung der
Kabinenadresse,