14
Operating Instructions - EmoTouch 3
Description of the units
EN
3.2 Technical data
* Fan and light connections are protected by a joint 2AF fuse.
Power supply
400 V 3 N AC 50 Hz
Switching output
Max. 9 kW resistive load, upgrade with LSG units possible
Fuse
3 x 16 A
Ambient temperature
-10°C to +35°C
S1 output
Max. 50 W/50 VA (no capacitive loads)
Supply for terminal area/sauna
heater connection
0.5–2.5 mm² rigid or flexible with wire-end ferrule, two conductors with identical
cross-section per terminal can be connected.
Terminal area WM, 3, 4, light, fan
0.34–2.5 mm² rigid or flexible with wire-end ferrule. Observe minimum cross-sec-
tions for fuse protection for the supply line.
Potential-free contact
Load rating of contact for resistive loads:
- Maximum power supply: 10 A
- Maximum voltage: 30 VDC/250 VAC
Storage temperature
-20°C to +60°C
Relay box housing
Plastic
Dimensions (H x W x D)
270 x 300 x 100 mm
Control panel: 142 x 210 x 42 mm, mounting depth approx. 37 mm
Weight
Relay box: approx. 1.5 kg
Relay box outputs/inputs
3 x RJ10 jack for sensor connection
2 x RJ14 jack for control panel and add-on modules
Control panel outputs/inputs
4 x RJ10 jack for relay box and multi-cabin connection
1 x connection for memory card (input/host, jack type A)
Connection for power adapter 24 V DC
Display
Colour capacitive 7" touchscreen display in 16:9 format
Error display: Text on the display
Heating time limitation
Up to 6 hrs/12 hrs/18 hrs/infinite
Temperature control
30°C–115°C (dry sauna mode)
30°C–70°C (humidity mode)
Humidity regulation
Time-proportionally or optionally according to % rel. air humidity with connected
humidity sensor
Sensor system
Digital sensor with safety temperature limiter 139°C
Control characteristics
Digital two-point control
Connection for fan*
Min. 5 W, max.150 W (only fan without starting capacitor)
Use only fans that are suitable for phase control, otherwise the fan or the control
unit can be damaged.
Connection for lighting*
Min. 5 W (20 mA), resistive load, max.
1 0 0 W
Dimmable energy-saving bulbs, max. 35 W
Light source with conventional transformers, max. 60 VA. Use only dimmable light
sources.