Operation
EN
5.4.3 Setting the humidity for Bi-O mode
An (optional) humidity sensor regulates the relative air humidity in %. At
the same time, the control unit attempts to keep the set humidity as pre-
cisely as possible.
Air humidity can be regulated depending on the installation:
If a humidity sensor is connected, the relative air humidity in % is set.
If no humidity sensor is connected, an interval is set. This interval
defines how long humidity mode is active in relation to the entire oper-
ating time.
The following icons are shown here:
With humidity sensor:
Humidity is regulated as shown in the following table:
All values that lie below or on the characteristic curve can be set and
used.
When setting a parameter, e.g. temperature, the setting for the other
parameter is automatically adjusted.
Values that lie above the characteristic curve cannot be set.
Characteristic curve for temperature/humidity according to EN 60335-2-53
Icons shown in the status bar
Humidity mode
Finnish mode
Icons shown in the sub-menu
With humidity sensor:
Air humidity in percentage during humidity
mode
Without humidity sensor:
Humidity interval in humidity mode
%
T
[°C]
rH
[%]
80
70
60
50
40
100
90
80
70
60
50
40
30
20