EN
1.2 Operation and settings
These operating instructions are intended for the personnel re-
sponsible for the operation of a sauna cabin. Observe the follow-
ing general safety instructions during set-up and operation.
Risk to life and limb
and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follow-
ing completion of the installation work.
The electrical installation of the relay box and other electrical
systems or equipment with a fixed mains connection must only
be performed by a trained electrician from an authorised elec-
trical company.
Observe the stipulations in VDE 0100 part 701.
The system must be disconnected and removed entirely from
the mains supply before commencing installation and repair
work.
The housing cover must only be removed by a specialist.
Fire hazard from
overheating
Insufficient ventilation can lead to device overheating and fire.
Flammable parts must not exceed a temperature of 140°C when
the unit is operated as intended or in the event of a malfunction.
Do not install control panels, relay boxes and modules in en-
closed cabinets or wood panelling.
Observe the sauna heater manufacturer's safety and installa-
tion instructions.
Observe the cabin manufacturer's safety and installation in-
structions.
Touchable glass surfaces on the outside of the cabins could
reach a maximum of 76°C. Attach safety devices if needed.
Damage to the unit
Corrosive or heavy saline atmospheres damage the contacts in the
control panel, in the relay box and in the sensors.
The control panel and sensors should not be installed in a cor-
rosive or heavy saline atmosphere.