Software Release: [App: 02.09.10051.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042;
BTL: 02.09.10015.00]
Section 40
48
00-02-0939
2019-06-13
Exercise Running Loaded Time
(Medium Security)
:
Time the operator sets for the engine to run if
voltage drops below the low voltage set point.
Factory set to 15 minutes
Communication (High Security)
Communication Type
(High Security)
:
PVA Gauge:
this function will be used if utilizing PVA Gauges on the RS485 Communications
Port.
Modbus:
this function will be used if using a SCADA or telemetry device for polling the Modbus
register list on the RS485 Communications Port. See Modbus Register Map.
Factory
Default.
Slave Address
(High Security)
:
This is the RS485 Modbus slave node number.
Factory set to 1
.
Serial Setup
(High Security)
:
Allows the operator to change the controller’s RS485 serial communication
settings.
Baudrate
(High Security)
:
Factory set to 19200
9600
19200
38400
57600
115200
Stopbits
(High Security)
:
Factory set to 1
0
1
2
Parity
(High Security)
: Factory set to None
None
Odd
Even
PV CAN Backlight Enable
(High Security)
:
allows the MPC-10 / TEC-10 to control the backlights of the
PVCAN gauges when used with the controller.
Factory set to Off
CAN Termination
(High Security)
:
allows the operator to enable or disable the controller’s internal 120 ohm
terminating resistor. This should be enabled if the MPC-10 / TEC-10 is located at the end of the CAN
bus and the end terminating resistor is not in the harness.
Factory set to Enable.
CAN Parameter Map
(High Security)
:
allows the operator to enable or disable the proprietary CAN
parameter map. The CAN Parameter Map can be used in place of the Modbus map when using a
CAN device to talk to the controller for starting, stopping and control functions via telematics or
another CAN based system. See CAN Parameter Map Section below for definition of the mapping.
Factory set to Disable.
CAN Baud rate
(High Security)
:
Factory set to 250 Kbps
10 Kbps
20 Kbps
50 Kbps
100 Kbps
125 Kbps
250 Kbps
500 Kbps
800 Kbps
1 Mbps