The Application Configuration menu is where an operator will
set up the controller’s Auto Start Functions
and Auto Throttling Methods, if the intended use is an auto start and/or auto throttling controller. Depending
on which application is chosen in the menu, there are certain auto start functions and auto throttling
methods hidden that are not pertinent to the application chosen. This automatic hiding feature allows for
a simpler, more intuitive controller menu in the MPC-10 / TEC-10. Review Application Configuration under
the Menu Glossary section of this manual for the full list and definition of each setting.
Pump All Purpose
The Pump All Purpose application houses auto start functions and auto throttling methods of the
controller for common pumps used in rental applications.
The auto start functions and auto throttle methods are:
Auto Start/Stop Functions
•
Single Contact (requires a digital input for start and stop)
•
Local Start (Green Start key)
•
Two Contact Maintained (Dual Floats) (requires digital inputs for start and stop)
•
Pressure Transducer (requires an analog input setting)
•
Level Transducer (requires an analog input setting)
Auto Throttle Methods
•
Running Loaded RPM
•
Pressure Transducer (requires an analog input setting)
•
Level Transducer (requires an analog input setting)
Air Compressor
The Air Compressor application houses the auto start functions and auto throttle methods meant
to be used on all engine-driven air compressor applications. The MPC-10 / TEC-10 allows for
the compressor to start/stop and maintain a desired pressure during operation.
The auto start functions and auto throttle methods to choose from are:
Auto Start/Stop Functions
•
Single Contact (requires a digital input for start and stop)
•
Local Start (Green Start key)
•
Pressure Transducer (requires an analog input setting)
Auto Throttle Methods
•
Running Loaded RPM
•
Pressure Transducer (requires an analog input setting)