PROGRAMMING
GUIDE
SOLARDRIVE
PLUS
35
/
107
2.5.2.
Motor Measures Menu
This menu contains speed values and electrical variables measured by the drive on the mains side, DC bus
and output.
M001
Speed Reference at Constant RPM
Range
32000 (integer part)
99 (decimal part)
32000.99 rpm
Note: The actual range depends on the value set in the parameters
for the motor max. speed and min. speed.
C028
–
C029
Motor 1
Active
Active only when a speed reference is used for the selected motor.
Address
1650 (integer part) 1651 (decimal part)
Function
Value of the speed reference obtained when the motor rotates at constant speed, once the preset
ramp time is over.
M002
Speed Ramp Output
Range
32000 (integer part)
99 (decimal part)
32000.99 rpm
Note: The actual range depends on the value set in the parameters
for the motor max. speed and min. speed.
C028
–
C029
Motor 1
Active
Active only when a speed reference is used for the selected motor.
Address
1652 (integer part) 1653 (decimal part)
Function
This is the measure of the speed value processed with respect to the ramp time.
M004
Motor Speed
Range
32000 (integer part)
99 (decimal part)
32000.99 rpm
Active
Always active.
Address
1654 (integer part) 1655 (decimal part)
Function
Motor speed value.
M006
Drive Output Frequency
Range
10000
1000.0 Hz (see Table 11)
Active
Always active.
Address
1656
Function
This is the measure of the voltage frequency output of the drive.
M026
Output Current
Range
0
65535
0
6553.5 A
Note: The actual range depends on the drive size.
Active
Always active.
Address
1676
Function
Measurement of the RMS of the output current.