2.2.4.
Parameter Modification
Factory setting allows parameter modification. The parameters included in the Parameters Menu (
Pxxx
parameters)
can be changed at any moment, whereas the parameters included in the Configuration Menu
(
Cxxx
,
Rxxx
,
Ixxx
parameters) can be changed only when the motor is stopped.
For safer operating conditions, the configuration parameters must be changed only when the drive is disabled
(the
ENABLE-A
and
ENABLE-B
commands are inactive): to do so,
P003
must be set to
0 (stand-by only)
.
To disable parameter changes, just change
P000
(write enable) and save its new setting.
P000
and
P002
(password) are both factory-set to 1. If
P000=0
, an inexpert user cannot change parameter values, but if
P000=1,
an advanced
user
will be able to change the parameter values.
For even safer operating conditions, you can change the password stored in
P002
; in that case, you must set
P000
accordingly.
NOTE
Note down and keep at hand the value set in P002.
Press the
SAVE/ENTER
key for parameter modifications; when a flashing cursor appears, press
▲
and
▼
to
change the parameter value. Do one of the following to quit the editing mode:
•
Press
ESC
with
P269b
= 0: [No]
the parameter value used by the drive is changed and is
maintained until the drive is shut down, then the value is lost when the drive is powered on again.
•
Press
ESC
with
P269b
=1: [YES]
the previous value
is restored.
•
Press SAVE/ENTER
the parameter value is used by the inverter and stored to non-volatile memory
and is not deleted when the drive is shut down.
Inputs (
Ixxx
) cannot be saved to non-volatile memory and are automatically set to their default values.
Rxxx
parameters become active only when the drive control board has been reset by pressing the
RESET
key for a few seconds or by switching off the drive
2.2.5.
Programming the Root Page
When the drive is turned on, the Root page is displayed as the starting page. The Root page allows you to
access the main menus (Measures, Parameters, Configuration, Product ID) or to shift to the Keypad pages
using the
MENU
key.
The first row shows the drive status (see
Root page
I N V E R T E R
O K
+
1 5 0 0 . 0 0 r p m
+
0 . 0 k W
M E A [ P A R ] C F
I D P
You can customise the root page using parameter
P265
(contact Enertronica Santerno).